Luna® Universal Probe One-Step RT-qPCR Kit

Catalog # Concentration Size List Price Quantity Your Price
E3006E 2500 reactions $3,097.00
$2,787.30
E3006L 500 reactions $811.00
$729.90
E3006S 200 reactions $361.00
$324.90
E3006X 1000 reactions $1,421.00
$1,278.90
Catalog # Size List Price Your Price
E3006E 2500 reactions $3,097.00
$2,787.30
E3006L 500 reactions $811.00
$729.90
E3006S 200 reactions $361.00
$324.90
E3006X 1000 reactions $1,421.00
$1,278.90
Catalog #
Qty:
 
*On-line ordering is for Canadian customers only. Web pricing is applicable only to orders placed online at www.neb.ca

Rapid, sensitive and precise probe-based qPCR detection and quantitation of target RNA targets. 

Make a simpler choice

  • One product per application simplifies selection
  • Convenient master mix formats and user-friendly protocols simplify reaction setup
  • Non-interfering, visible tracking dye helps to eliminate pipetting errors

Experience best-in-class performance

  • All Luna® products have undergone rigorous testing to optimize specificity, sensitivity, accuracy and reproducibility
  • Products perform consistently across a wide variety of sample sources
  • A comprehensive evaluation of commercially-available qPCR and RT-qPCR reagents demonstrates superior performance of Luna products

Optimize your RT-qPCR with Luna WarmStart® Reverse Transcriptase

  • Novel, thermostable reverse transcriptase (RT) improves performance 
  • WarmStart RT paired with Hot Start Taq increases reaction specificity and robustness
Featured Videos
View Video Library


The Luna Universal Probe One-Step RT-qPCR Kit is optimized for real-time quantitation of target RNA sequences using hydrolysis probes. One-Step RT-qPCR provides a convenient and powerful method for RNA detection and quantitation. In a single tube, RNA is first converted to cDNA by a reverse transcriptase, and then a DNA-dependent DNA polymerase amplifies the cDNA, enabling quantitation via qPCR. Probe-based qPCR/RT-qPCR monitors an increase in fluorescence upon 5´ → 3´ exonuclease cleavage of a quenched, target-specific probe to measure DNA amplification at each cycle of a PCR. At a point where the fluorescence signal is confidently detected over the background fluorescence, a quantification cycle or Cq value can be determined. Cq values can be used to evaluate relative target abundance between two or more samples, or to calculate absolute target quantities in reference to an appropriate standard curve derived from a series of known dilutions.

In the Luna Universal One-Step Probe RT-qPCR Kit, Hot Start Taq DNA Polymerase is combined with a novel WarmStart-activated reverse transcriptase, allowing dual control of enzyme activity via reversible, aptamer-based inhibition. This temperature-dependent activation helps to prevent undesirable non-specific priming and extension prior to thermocycling, providing added security for setting up reactions at room temperature. The engineered Luna WarmStart Reverse Transcriptase also possesses higher thermostability than many other RTs, allowing an optimal reaction temperature of 55°C. For difficult targets/templates, higher RT step temperatures of up to 60°C can be used without compromising Luna performance.
 
Note that to ensure full activation of the Luna WarmStart RT, incubation at temperatures lower than 50°C is not recommended.

The Luna Universal Probe One-Step Reaction Mix is supplied at 2X concentration and contains Hot-Start Taq DNA Polymerase, dNTPs, and all required buffer components. It is formulated with a unique passive reference dye that is compatible across a variety of instrument platforms, including those that require a high or low ROX reference signal. The Reaction Mix also features dUTP for carryover prevention and a non-fluorescent visible dye for monitoring reaction setup. This visible dye does not overlap spectrally with fluorophores commonly used in qPCR and does not interfere with real-time detection.

The Luna WarmStart RT Enzyme Mix is supplied at 20X concentration and contains Luna WarmStart Reverse Transcriptase as well as Murine RNase Inhibitor to aid in preventing RNA degradation (see also template preparation in product manual). It is compatible with various RNA sample types (total RNA, poly(A)-RNA, etc.) and sources.

.

Figure 1: The Luna Universal Probe One-Step RT-qPCR Kit offers exceptional sensitivity, reproducibility and RT-qPCR performance
RT-qPCR targeting human GAPDH was performed using the Luna Universal Probe One-Step RT-qPCR Kit over an 8-log range of input template concentrations (1 μg – 0.1 pg Jurkat total RNA) with 8 replicates at each concentration. Reaction setup and cycling conditions followed recommended protocols, including a 10-minute RT step at 55°C for the thermostable Luna WarmStart Reverse Transcriptase.


Figure 2: The Luna Universal Probe One-Step RT-qPCR Kit offers robust performance in multiplex applications
Luna
Multiplex RT-qPCR targeting human GAPDH, ribosomal protein L32g and PI3-Kinase-Related Kinase SMG1 was performed using the Luna Universal Probe One-Step RT-qPCR Kit over a 7-log range of input template concentrations (1 μg – 1 pg Jurkat total RNA) with 4 replicates at each concentration. Amplification plots are shown both overlayed (left) and for each multiplex target (right). To account for copy number differences, 0.4 µM primer was used for lower-copy target (SMG1) and 0.2 µM primer for higher-copy targets (L32g and GAPDH). Luna maintains superior efficiency, reproducibility, sensitivity and performance in multiplex RT-qPCR.



Figure 3: Extensive performance evaluation of commercially available probe-based RT-qPCR reagents demonstrates the robustness and specificity of Luna
Luna
Commercially-available RT-qPCR reagents were tested on 7 RT-qPCR targets varying in abundance, length, and %GC. Data was collected by 2 users and according to manufacturer’s recommendations. Results were evaluated for efficiency, low input detection and lack of non-template amplification (where ΔCq = average Cq of non-template control – average Cq of lowest input). In addition, consistency, reproducibility and overall curve quality were assessed (Quality Score). Bar graph indicates % of targets that met acceptable performance criteria (indicated by green box on dot plot and Quality Score > 3). Results for NEB and other suppliers are shown: Quanta, qScript XLT 1-Step RT-qPCR ToughMix®; ABI, TaqMan® RNA-to-Ct 1-Step Kit; QIAGEN, QuantiFast® Probe RT-PCR Kit; Bio-Rad, iTaq Universal Probes One-Step Kit; Promega®, GoTaq® Probe 1-Step RT-qPCR System. The Luna Universal Probe One-Step RT-qPCR Kit outperformed all other reagents tested.

Learn more about our comprehensive qPCR/RT-qPCR testing and “dots in boxes” data visualization.
Reagents Supplied

The following reagents are supplied with this product:

NEB # Component Name Component # Stored at (°C) Amount Concentration
  Luna® WarmStart® RT Enzyme Mix M3002SVIAL -20 1 x 0.2 ml 20 X
  Luna® Universal Probe One-Step Reaction Mix M3006SVIAL -20 2 x 1 ml 2 X
  Nuclease-free Water B1502AVIAL -20 1 x 1.5 ml
  Luna® WarmStart® RT Enzyme Mix M3002LVIAL -20 1 x 0.5 ml 20 X
  Luna® Universal Probe One-Step Reaction Mix M3006SVIAL -20 5 x 1 ml 2 X
  Nuclease-free Water B1502AVIAL -20 3 x 1.5 ml
  Luna® WarmStart® RT Enzyme Mix M3002LVIAL -20 2 x 0.5 ml 20 X
  Luna® Universal Probe One-Step Reaction Mix M3006SVIAL -20 10 x 1 ml 2 X
  Nuclease-free Water B1502AVIAL -20 6 x 1.5 ml
  Luna® WarmStart® RT Enzyme Mix M3002EVIAL -20 2 x 1.25 ml 20 X
  Luna® Universal Probe One-Step Reaction Mix M3006EVIAL -20 1 x 25 ml 2 X
  Nuclease-free Water B1502EVIAL -20 1 x 25 ml

Properties & Usage



Notes
  • Primer Design
    The use of qPCR primer design software (e.g., Primer3) maximizes the likelihood of amplification success while minimizing nonspecific amplification and primer dimers. Targets with balanced GC/AT content (40–60%) tend to amplify most efficiently. Where possible, enter sufficient sequence around the area of interest to permit robust primer design and use search criteria that permit cross-reference against relevant sequence databases (to avoid potential off-target amplification). It is advisable to design primers across known RNA splicing sites in order to prevent amplification from genomic DNA.
  • Primer and Probe Concentrations
    For most targets, a final concentration of 400 nM (each primer) will provide optimum performance. If needed, primer concentrations can be optimized between 100–900 nM. Probe should be included at 200 nM for best results. Probe concentration can be optimized in the range of 100–500 nM.
  • Multiplexing
    When determining which fluorophores to include in a multiplex reaction, be sure to choose compatible reporter dyes and quenchers (e.g., those that can be accommodated by the chosen real-time instrument with minimal overlap in fluorescence spectra). For ROX-dependent instruments, avoid ROX-labeled probes. Include 400 nM of forward and reverse primers and 200 nM probe for each target to be detected in the reaction. For targets that differ significantly in abundance, use of a lower primer concentration (e.g. 200 nM) for the more abundant target(s) is recommended. Adjust concentrations if necessary based on performance (primer 100–900 nM, probe 100–500 nM). When loading a qPCR protocol onto the real-time instrument, be sure to select the appropriate optical channels, as some instruments have a single channel recording mode that would prevent multiplex data collection and analysis. The functionality of the primer and probe sets should be tested individually before attempting a multiplex reaction.
  • Amplicon Length
    To ensure successful and consistent qPCR results, it is important to maximize PCR efficiency. An important aspect of this is the design of short PCR amplicons (typically 70–200 bp). Some optimization may be required for targets that exceed that range.
  • Template Preparation and Concentration
    Luna RT-qPCR is compatible with RNA samples prepared through typical nucleic acid purification methods. Prepared RNA should be stored in an EDTA-containing buffer (e.g., 1X TE) for long-term stability, and dilutions should be freshly prepared for a qPCR experiment in either TE or water. Note that the quality of RNA templates can greatly affect RT-qPCR efficiency. RNA should be handled with appropriate precautions to prevent RNase or DNase contamination. Use of nuclease-free water (provided) is strongly recommended. Where useful, RNA may be treated with DNase I to remove contaminating genomic DNA.
    Generally, a useful concentration of standard and unknown material will be in the range of 108 copies to 10 copies. Note that for dilutions in the single-copy range, some samples will contain multiple copies and some will have none, as defined by the Poisson distribution. For total RNA, Luna One-Step Kits can provide linear quantitation over an 8-order input range of 1 μg – 0.1 pg. For most targets, a standard input range of 100 ng – 10 pg total RNA is recommended. For purified mRNA, input of ≤ 100 ng is recommended. For in vitro-transcribed RNA, input of ≤ 109 copies is recommended.
  • ROX Reference Dye

    Some real-time instruments recommend the use of a passive reference dye (typically ROX) to overcome well-to-well variations that could be caused by machine limitations such as “edge effect”, bubbles, small differences in volume, and autofluorescence from dust or particulates in the reaction. However, ROX normalization does little to the variations caused by pipetting errors of templates/primers, heterogeneous mixing, and evaporation/condensation issues.

    A universal passive reference dye is included in the following Luna® qPCR products: Luna Universal qPCR Master Mix (NEB #M3003), Luna Universal Probe qPCR Master Mix (NEB #M3004), Luna Universal One-Step RT-qPCR Kit (NEB #E3005), and Luna Universal Probe One-Step RT-qPCR Kit (NEB #E3006). These products support broad instrument compatibility (High-ROX, Low-ROX, ROX-independent) so no additional ROX is required for normalization.

    The Luna Probe One-Step RT-qPCR Kit (No ROX) (E3007) contains no reference dye and is compatible with any instrument that does not require ROX. If ROX normalization is needed, ROX can be added. Please refer to instrument manufacturer’s instructions for greater details.

  • Carryover Contamination Prevention
    RT-qPCR is an extremely sensitive method, and contamination in new RT-qPCR assays with products from previous amplification reactions can cause a variety of issues, such as false positive results and a decrease in sensitivity. The best way to prevent this “carryover” contamination is to practice good laboratory procedures and avoid opening the reaction vessel post amplification. However, to accommodate situations where additional anti-contamination measures are desired, Luna qPCR mixes contains a mixture of dUTP/dTTP that results in the incorporation of dU into the DNA product during amplification. Pretreatment of qPCR/RT-qPCR experiments with uracil DNA glycosylase (UDG) will eliminate previously-amplified uracil-containing products by excising the uracil base to produce a non-amplifiable DNA product. The use of a thermolabile UDG is important, as complete inactivation of the UDG is required to prevent destruction of newly synthesized qPCR products.

    To enable carryover prevention, 0.025 units/μl Antarctic Thermolabile UDG (NEB #M0372) should be added to the reaction mix. To maximize elimination of contaminating products, set up the qPCR experiments at room temperature or include a 10 minute incubation step at 25°C before the initial denaturation step.
  • Reaction Setup and Cycling Conditions
    Due to dual hot-start feature of Luna One-Step Kits, it is not necessary to set up reactions on ice or preheat the thermocycler prior to use.
    For 96-well plates, a final reaction volume of 20 μl is recommended.
    For 384-well plates, a final reaction volume of 10 μl is recommended.
    When programming instrument cycling conditions, ensure a plate read is included at the end of the extension step, and a denaturation (melt) curve after cycling is complete to analyze product specificity.
    Amplification for 40 cycles is sufficient for most applications, but for very low input samples 45 cycles may be used.
Web Tools
FAQs
Quality Control Assay
Quality Control tests are performed on each new lot of NEB product to meet the specifications designated for it. Specifications and individual lot data from the tests that are performed for this particular product can be found and downloaded on the Product Specification Sheet, Certificate of Analysis, data card or product manual. Further information regarding NEB product quality can be found here.
Specifications
The Specification sheet is a document that includes the storage temperature, shelf life and the specifications designated for the product. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]
Certificate of Analysis
The Certificate of Analysis (COA) is a signed document that includes the storage temperature, expiration date and quality controls for an individual lot. The following file naming structure is used to name these document files: [Product Number]_[Size]_[Version]_[Lot Number]
Legal And Disclaimer

Products and content are covered by one or more patents, trademarks and/or copyrights owned or controlled by New England Biolabs, Inc (NEB). The use of trademark symbols does not necessarily indicate that the name is trademarked in the country where it is being read; it indicates where the content was originally developed. The use of this product may require the buyer to obtain additional third-party intellectual property rights for certain applications. For more information, please email busdev@neb.com.

This product is intended for research purposes only. This product is not intended to be used for therapeutic or diagnostic purposes in humans or animals.

New England Biolabs (NEB) is committed to practicing ethical science – we believe it is our job as researchers to ask the important questions that when answered will help preserve our quality of life and the world that we live in. However, this research should always be done in safe and ethical manner. Learn more.Nucleic acid-based aptamers for use with thermophilic DNA polymerases and reverse transcriptases are licensed exclusively by New England Biolabs, Inc. from SomaLogic, Inc. New England Biolabs, Inc. gives the Buyer/User a non-exclusive license to use the Luna Universal Probe One-Step RT-qPCR Kit for Research Use Only (RUO). Commercial use of this product may require a license from New England Biolabs, Inc. For additional information or to inquire about commercial use, please contact busdev@neb.com. BIO-RAD® and ITAQ® are registered trademarks of Bio-Rad Laboratories.
GOTAQ® is a registered trademark of Promega Corporation.
QIAGEN® and QUANTIFAST® are registered trademarks of Qiagen, Inc.
QSCRIPT is a trademark of Quanta.
QUANTSTUDIO® is a registered trademark of Life Technologies Corporation.
STEPONEPLUS® is a registered trademark of Applied Biosystems, LLC.
TOUGHMIX® is a registered trademark of Quanta.
TAQMAN® is a registered trademark of Thermo Fisher Scientific.

Top