Standard Cleanup Protocol using the Monarch® Spin PCR & DNA Cleanup Kit and Centrifugation (NEB #T1130)
Buffer Preparation
Prepare buffers as recommended in Buffer Preparation Guidance.
Standard Cleanup Protocol using Centrifugation
- Add 5 volumes (e.g., 250 μl) of Monarch Buffer BZ to 1 volume (e.g., 50 μl) of sample. Mix well by pipetting up and down or flicking the tube. Do not vortex. Using a sample volume of 20-100 μl is recommended. For samples less than 20 μl, adjust the volume with TE or nuclease-free water to 20-100 μl. For diluted samples larger than 800 μl, load 800 μl first, proceed with step 2, and repeat as needed.
- Insert the Monarch Spin Column S1A into the Monarch Spin Collection Tube and load the sample onto the column. Spin for 1 minute, then discard the flow-through.
- Re-insert the column into the collection tube. Wash by adding 200 μl of Monarch Buffer WZ and spin for 1 minute. Discarding flow-through is optional.
- Repeat wash (step 3).
- Transfer the column to a clean 1.5 ml microfuge tube. Use care to ensure that the tip of the column does not touch the flow-through. If in doubt, re-spin for 1 minute.
- Add 5-20 μl of Monarch Buffer EY to the center of the matrix to elute DNA. Wait for 1 minute, and spin for 1 minute. Nuclease-free water can also be used to elute the DNA. Yield may slightly increase if a larger volume of Monarch Buffer EY is used, but the DNA will be less concentrated. For larger size DNA (≥ 15 kb), incubate the column with elution buffer at room temperature for 5 minutes to maximize the yield. Alternatively, heating the elution buffer to 50°C prior to use can be used.